Alsynite Fire Retardant GRP Sheeting
Product Range Performance Technical Data
 
Product Range

The ALSYNITE range of 50FR and 25HTH resin systems can be applied to the full range of Alsynite profiles in line with standard nominal weights. Typically, any of the Alsynite surface coating systems (ULTRA, ULTRA-Cool, ULTRA Evercool, TEDLAR®, GEL COAT 60GC and R74) are fully compatible with 50FR and 25HTH fire retardant resin systems. Special sheet sizes, profiles and colours can be produced, subject to commercial viability and pigment availability.

ALSYNITE 50FR

The Alsynite 50FR Resin System has been specifically formulated for commercial and industrial building applications. The sheeting allows the transmission of natural light into the interior of a building while providing a fire retardant feature at minimal additional cost. Alsynite 50FR can be specified to comply with relevant fire standards. Pearl in colour, Alsynite 50FR incorporates a specific fire retardant formulation. As a result, it complies without restriction to the General Requirements of Class 2 to 9 buildings of the Building Code of Australia.

ALSYNITE 25HTH

The Alsynite 25HTH fire retardant resin system has been specifically formulated for industrial and commercial applications. The sheeting can be translucent or opaque in colour.

 
   
Features & Benefits
 
Applications

 

Performance
Performance

ALSYNITE 50FR

When tested in accordance with AS 1530.3 ‘Test For Early Fire Hazard Properties Of Materials’ Alsynite 50FR gives the following determinations:

AS1530.3 TEST RESULTS
Ignitability Index 15
Spread Of Flame Index 9
Heat Evolved Index 10
Smoke Developed Index 7

ALSYNITE 25HTH

Alsynite 25HTH resin system incorporates a specific fire retardant formulation. As a result, Alsynite 25HTH conforms with Underwriters Laboratory U.L. Standard 723 ‘Test For Surface Burning Characteristics Of Building Materials’. (ASTM E84).

In line with the above test method, Alsynite 25HTH resin system has a Flame Spread Index of 25. ‘Factory Mutual Melbourne Engineering Bulletin’ states “the use of Alsynite’s 25HTH GRP has been pre-approved for use in FR treated panels, skylights and wall linings with the Flame Spread Rating of 25 or less as per ASTME-84”.

 

 

Technical Data

QUALITY AND TESTING

50FR and 25HTH are totally developed by Alsynite. They are formulated to meet both local and international conditions and have been subjected to rigorous testing for compliance with relevant Australian and American Standards.

Technical assistance is available from Alsynite’s manufacturing facility in North Rocks, NSW, Australia.

Alsynite set a new benchmark in industry standards by providing an individual Certificate of Compliance in relation to all of its Fire Retardant resin systems. Furthermore, Alsynite provides the following third party confirmations of Resin Supplier, Resin Batch Number, Date Of Manufacture and Sheet Description. Alsynite was the first roofing products supplier to invite industry confirmation and scrutiny on the supply of its base materials. Our Certificate of Compliance is signed by two resident Directors independant of the manufacturing process. To ensure peace of mind and recognising your Duty of Care (DOC), insist on a Certificate outlining all third party confirmations.

 

PROFESSIONAL INDEPENDANT CERTIFICATION CERTIFICATES OF COMPLIANCE

 

  © Copyright (2007) Laserlite. All rights reserved. Laserlite Australia | Contact Us | Sitemap | Home